Finally, A Choice In Direct-to-Deck Roof Insulation

With the release of ICC-ES Evaluation Report ESR-1025, STYRO-STOP Direct expanded polystyrene (EPS) insulation can be applied directly over steel roof decks, without a thermal barrier. This makes STYRO-STOP Direct the most cost-effective steel deck roofing insulation on the market. Enjoy the benefits of exceptional design flexibility, permanent high R-Values, superior dimensional stability, and resistance to moisture absorption and physical degradation at a substantial cost savings over other insulation products.

STYRO-STOP Direct is compatible with all major roofing materials and assemblies. It is available in flat, tapered and compound tapered panels in densities ranging from 1.00 to 2.00 pcf, and is manufactured under strict quality controls. Having completed thorough evaluation for fire safety performance by ICC Evaluation Services, STYRO-STOP Direct provides building owners, architectural specifiers and contractors the confidence that comes from its recognition by the nation's most respected code authority.

 

 
       
 

Fire Safety Performance

STYRO-STOP Direct has undergone thorough evaluation by ICC-ES for fire-safety performance and can be installed directly over metal roof decks in ballasted, mechanically fastened and fully-adhered roof assemblies.

ICC-ES Code Acceptance

ICC-ES has accepted STYRO-STOP Direct for use directly over steel roof decks as a component of a Class A, B or C roof covering. Details of the ICC-ES acceptance are as follows:

  • Assemblies: Ballasted, mechanically fastened, or fully-adhered
  • Maximum Insulation Thickness: 9 inches at 1.00 PCF; 7.2" at 1.25 PCF; 6" at 1.50 PCF; 4.5" at 2.00 PCF
  • Steel Deck: Minimum 22 gauge, 1 1/2 inch deep, non-perforated with flutes spaced a maximum of 6 inches O.C.
  • Cover Board: 1/4 inch thick Dens-Deck, manufactured by Georgia-Pacific (fully-adhered and mechanically fastened)
  • Accepted Membranes: Any ICC-ES approved EPDM or thermoplastic single-ply
  • Fire Extinguishing System: Building must be equipped with a wet-pipe sprinkler system
  • Informational placards must be placed at roof entry points to notify roofing contractor that re-roofing limits exist

For complete assembly information, please refer to ICC-ES Evaluation Report ESR-1025

Discover The Benefits Of STYRO-STOP Direct Insulation

  • The lowest cost per R-Value of any rigid insulation board provides high insulating values that will not diminish over time.
  • Superior dimensional stability helps assure that your roof insulation system remains tight and energy-efficient, and your membrane fully supported.
  • Resistant to the effects of moisture, yet it breathes, is not a vapor barrier and needs no venting.
  • Compressive strengths ranging from 10 - 25 psi that can accommodate specific roof traffic and loads without deforming.
  • Sizes that offer more slope and dimension options than other insulations.
  • Independent test reports document superior in-situ performance in a wide variety of roof applications.

Product Specification

7220 - Roof Deck Insulation: STYRO-STOP Direct is available in tapered and flat panels and in a variety of slopes. Ideal for use in ballasted, mechanically fastened and fully-adhered roof assemblies.

Product Dimensions

STYRO-STOP Direct is available in a range of sizes to meet your specific application:
Thickness: 1/4 inch - 9 inches
Width: 24 inches - 48 inches
Length: 48 inches - 96 inches

Environmental Assurance

STYRO-STOP does not contain ozone depleting CFCs or HCFCs.

Technical Data

Design Considerations

Physical Properties

 

Ballasted Roof Assembly
 
Mechanically Fastened Roof Assembly
 
Fully-Adhered Roof Assembly

 

Factory fabricated hip and valley panels eliminate time consuming field fabrication of mitered corners.

 

 
 

 